critical power100KVA/100KW Three phase input/three-phase outputHigh frequency IGBT rectifier
critical power100KVA/100KW,Three phase input/three-phase output,Online (dual conversion),High frequency IGBT rectifier,Rated input voltagethree-phase:rated 230/400Vac(220/380,240/415 optional),input frequency50/60Hz,range 40-72Hz,apply toLarge and medium-sized enterprise data center computer rooms, server clusters, storage devices, network core nodes, virtualization platforms, cloud computing resource pools, bank branch transaction systems, ATM fleet, financial data center, factory production line PLC control system, industrial robots, precision machining equipment, semiconductor production workshop, 5G base station, core computer room, hospital operating room equipment, medical imaging system CT/MRI, laboratory, subway signal system, airport ground power supply, high-speed rail dispatch center, cloud computing center, AI computing power cluster, big data storage center, petroleum and petrochemical plant DCS system, power substation control equipment, steel smelting production line, ur
Buy Now
- Telephone:4001177032
- Email:19710409880@139.com
Product details
SANTAK critical power 3C3 HD-100K Full version 4BRK,is a kind of Uninterruptible power systemproducts.Its topology was Online (dual conversion),Long lasting model (external battery),Three phase input/three-phase output,High frequency IGBT rectifier,It belongs to SANTAK CASTLE 3C3 HD Series 20-600kVA.Its rated capacity and maximum load power was 100KVA/100KW,Input/output voltage phase was Three phase input/three-phase output,Input method was Three phase+N wire+ground wire(L1/L2/L3/N/G).Rated voltage was three-phase:rated 230/400Vac(220/380,240/415 optional).Input Voltage was 190/330~276/478Vac(-15%,+20%)100% load;116/201~276/478Vac(-50%,+20%),50% load,Input frequency was 50/60Hz,range 40-72Hz,THDI was <3%linear load; <5%Nonlinear load,Input power factor was ≥ 0.99,Bypass voltage was three-phase:rated 230/400Vac(220/380,240/415 optional),Bypass input voltage range:195/338~264/458Vac(Default range rated voltage±15%,Maximum optional range±20%),Output voltage was three-phase:rated230/400Vac(220/380,240/415optional),Output accuracy was ±1%,Output frequency was 50或60Hz±0.1%,User configurable,Peak output current ratio was 3:1,Output waveform distortion was 100%linear load<1%;100%Nonlinear load<5%,Output power factor PF=1,Overload capacity:102~110%Load for 60 min,111~125%Load for 10 min,126~150%Load for 1 min,>151%Load for 150ms,Efficiency:online mode:Up to 96%;ECO mode:Up to 99%,Conversion time:0ms(online mode-battery mode);<0ms(battery mode-bypass mode),Battery type:VRLA lead-acid batteries, AGM, Colloidal battery, NiCad battery, lithium battery,Battery DC voltage±192VDC-±264VDC;32-44pcs battery,Even numbers can only be adjusted, default384VDC(32pcs),Charging method was Intelligent battery management ABM or float charging,Charging current:Max 100A configurable,Discharge cut-off voltage:1.67VPC 至 1.75 VPC, Automatically adjust according to the discharge rate.,Battery cold start:Y,Battery usage environment:discharge:-20℃~+50℃;charge:0℃~+40℃;storage:-15℃~+40℃;Recommended working and storage temperatures:+25℃,Display:Equipped with a full-color touch screen and cool LED status indicator lights, it is convenient for users to check the device's operating status and maintenance operations,Protection level:IP20.Operating temperature:0~40℃ (40~50℃ Need to reduce the amount),Relative humidity:0-95% No condensation,UPS Dimensions:500*850*1230mm (W*D*H),UPS Net weight:149kg,Audio noise :<78.8dB @ Distance of 1 meter,Operating altitude:0~3000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output,Execution standards:GB4943; YD/T1095; GB/7260.2; IEC/62040-2.Communication and monitoring:Standard AS400/RS232 card (included accessories), RS232/USB service dedicated interface; Mini Slot communication card slot * 2; CN10: Terminal CN10 contains parallel CAN communication signals, Pull Chain signals, and REPO signals.,Optional Accessories:Mini Slot communication card: industrial network checkpoint, second-generation gigabit network card, second-generation environmental probe; Dust filter screen; Temperature sensor; Seismic components,Parallel redundancy(optional):Max can install 4 UPS units; Shared battery pack,Warranty was 3 Years.Application scenarios:Large and medium-sized enterprise data center computer rooms, server clusters, storage devices, network core nodes, virtualization platforms, cloud computing resource pools, bank branch transaction systems, ATM fleet, financial data center, factory production line PLC control system, industrial robots, precision machining equipment, semiconductor production workshop, 5G base station, core computer room, hospital operating room equipment, medical imaging system CT/MRI, laboratory, subway signal system, airport ground power supply, high-speed rail dispatch center, cloud computing center, AI computing power cluster, big data storage center, petroleum and petrochemical plant DCS system, power substation control equipment, steel smelting production line, urban rail transit power system, airport terminal power supply, government emergency command center, supercomputer, particle accelerator, astronomical observation equipment, broadcasting and television station control center, content distribution network (CDN) nodes, streaming media server cluster, photovoltaic power station, energy storage PCS system, wind power generation
Product Features
- Efficient and energy-saving design: Online efficiency of 96%, ECO mode of 99%, output power factor of 1.0, load capacity increased by 10%.
- Ultimate Space Optimization: Modular architecture reduces volume by 90% and footprint by 50%, suitable for high-density data center deployment.
- Intelligent mode switching: ECO/dual conversion mode automatically switches within 2-4ms, ensuring power quality while reducing energy consumption by 40%.
- Long term battery management: Supports lead-acid/lithium batteries, 4x fast charging+intelligent sleep mode, extending battery life by 50%.
- Industrial grade reliability: capacitor health warning+PCBA three proof coating, suitable for high salt spray, dust and corrosive environments.
- Intelligent redundant parallel: supports 4 master-slave parallel machines, with smaller circulating current and an average current accuracy of ± 1%, ensuring high system availability.
- Full scenario compatibility: compatible with MODBUS/BMS systems, with gigabit network cards for remote monitoring and emergency shutdown functions.
- Low carbon environmental certification: meets carbon peak/carbon neutrality targets, reduces TCO by 30%, and meets UL fire and dust prevention standards.
Application Scenarios
- Large and medium-sized enterprise data center computer rooms, server clusters, storage devices, network core nodes, virtualization platforms, cloud computing resource pools, bank branch transaction systems, ATM fleet, financial data center, factory production line PLC control system, industrial robots, precision machining equipment, semiconductor production workshop, 5G base station, core computer room, hospital operating room equipment, medical imaging system CT/MRI, laboratory, subway signal system, airport ground power supply, high-speed rail dispatch center, cloud computing center, AI computing power cluster, big data storage center, petroleum and petrochemical plant DCS system, power substation control equipment, steel smelting production line, urban rail transit power system, airport terminal power supply, government emergency command center, supercomputer, particle accelerator, astronomical observation equipment, broadcasting and television station control center, content distribution network (CDN) nodes, streaming media server cluster, photovoltaic power station, energy storage PCS system, wind power generation
Product Parameters
- Brand:SANTAK
- Product-type:Uninterruptible power system
- Series:SANTAK CASTLE 3C3 HD Series 20-600kVA
- Topology:Online (dual conversion)
- Backup type:Long lasting model (external battery)
- System:Three phase input/three-phase output
- Product Category:High frequency IGBT rectifier
- Model:3C3 HD-100K Full version 4BRK
- Load power(max):100KVA/100KW
- Input/output voltage phase:Three phase input/three-phase output
- Input method:Three phase+N wire+ground wire(L1/L2/L3/N/G)
- Rated voltage:three-phase:rated 230/400Vac(220/380,240/415 optional)
- Input Voltage:190/330~276/478Vac(-15%,+20%)100% load;116/201~276/478Vac(-50%,+20%),50% load
- Input frequency:50/60Hz,range 40-72Hz
- THDI:<3%linear load; <5%Nonlinear load
- Input power factor:≥ 0.99
- Bypass voltage:three-phase:rated 230/400Vac(220/380,240/415 optional)
- Bypass input voltage range:195/338~264/458Vac(Default range rated voltage±15%,Maximum optional range±20%)
- Bypass input frequency range:50/60Hz,range40-72Hz
- Output voltage:three-phase:rated230/400Vac(220/380,240/415optional)
- Output accuracy:±1%
- Output frequency:50或60Hz±0.1%,User configurable
- Peak output current ratio:3:1
- Output waveform distortion:100%linear load<1%;100%Nonlinear load<5%
- Output power factor:PF=1
- Overload capacity:102~110%Load for 60 min,111~125%Load for 10 min,126~150%Load for 1 min,>151%Load for 150ms
- Efficiency:online mode:Up to 96%;ECO mode:Up to 99%
- Conversion time:0ms(online mode-battery mode);<0ms(battery mode-bypass mode)
- Battery type:VRLA lead-acid batteries, AGM, Colloidal battery, NiCad battery, lithium battery
- Battery DC voltage:±192VDC-±264VDC;32-44pcs battery,Even numbers can only be adjusted, default384VDC(32pcs)
- Charging method:Intelligent battery management ABM or float charging
- Charging current:Max 100A configurable
- Discharge cut-off voltage:1.67VPC 至 1.75 VPC, Automatically adjust according to the discharge rate.
- Battery cold start:Y
- Battery usage environment:discharge:-20℃~+50℃;charge:0℃~+40℃;storage:-15℃~+40℃;Recommended working and storage temperatures:+25℃
- Display:Equipped with a full-color touch screen and cool LED status indicator lights, it is convenient for users to check the device's operating status and maintenance operations
- UPS Dimensions(W×D×H)(mm):500*850*1230
- UPS Net weight(kg):149kg
- Operating temperature:0~40℃ (40~50℃ Need to reduce the amount)
- Storage temperature:-15~55℃
- Relative humidity:0-95% No condensation
- Audio noise (at a distance of 1 meter):<78.8dB @ Distance of 1 meter
- Protection level:IP20
- Operating altitude:0~3000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output
- Execution standards:GB4943; YD/T1095; GB/7260.2; IEC/62040-2
- Communication and monitoring:Standard AS400/RS232 card (included accessories), RS232/USB service dedicated interface; Mini Slot communication card slot * 2; CN10: Terminal CN10 contains parallel CAN communication signals, Pull Chain signals, and REPO signals.
- Optional Accessories:Mini Slot communication card: industrial network checkpoint, second-generation gigabit network card, second-generation environmental probe; Dust filter screen; Temperature sensor; Seismic components
- Parallel redundancy(optional):Max can install 4 UPS units; Shared battery pack
- Warranty:3 Years
- Note-1:When the battery is not used for a long time at room temperature and has not been charged for three consecutive months, it needs to be charged once; In high temperature environments, if not charged for two consecutive months, it is necessary to charge it once, with a minimum of 10 hours each time; Do not discharge without load, the continuous discharge time of the battery should not exceed 14 hours.
- Note-2:This product is used in Class C2 environments and requires additional measures to suppress electromagnetic interference. This product is suitable for C3 class environments, including all commercial and industrial environments.