Product details

SANTAK Photovoltaic power station UPS PT3KSLI-i,is a kind of Uninterruptible power systemproducts.Its topology was Lithium battery UPS,Online (dual conversion),Standard model,Single phase input, single-phase output,Its installation method was Vertical/Tower/Horizontal/rack mounted,It belongs to SANTAK PT3000 LoT series PT1-3K.Its rated capacity and maximum load power was 3000VA/3000W,Input method was Single phase two-wire+grounded (L+N+PE).Rated voltage was (200Vac/208Vac/220Vac/230Vac/240Vac (defult220Vac).Input Voltage was 160-300V 100%load, 110-160V Linear derating to50%load,Input frequency was 45 Hz– 55 Hz(50Hz)/54 Hz – 66 Hz(60Hz),THDI was < 5% Nonlinear full load,Input power factor was ≥ 0.99,Bypass voltage was 187VAC~264VAC,Output voltage was 220Vdefult(200/208/220/230/240 VAC optional),Output accuracy was ± 1 %,Output Connection was Main output (1 x IEC C19 + 4 x IEC C13) Partition control output ( 4 x IEC C13),Output frequency range (mains mode) was 50Hz/60Hz adaptive,Output frequency range (battery mode) was 50Hz/60Hz adaptive,Peak output current ratio was 3:1,Output waveform distortion was <1%(linear load;<5%(Nonlinear load),Output power factor was PF = 1,Output waveform was Pure sine output,Overload capacity (mains 25 ℃, output power factor 0.8):100%150% 500ms,Efficiency:online mode:Up to 93%;ECO mode:Up to 97%,Battery voltage × number of batteries:76.8VDC/No built-in battery,EBM mode was PTLB07228,EBM max number was 4 PCS Max,Hot swappable battery:Y,Battery charging temperature compensation:Y,Battery backup time (25 ℃) was 1*EBM,Half load ≤60min;full load ≥30min,Battery charging time was 3.8hour recharge to 90%,Display:LCD+LED can digitally display load/power/input/output parameters, text and graphical display of operating modes,Rack mounted installation height:2U,Protection level:IP20,Conversion time (mains<>battery) was 0ms@Online mode to Battery mode; 4ms @Online mode to Bypass mode; 10ms @ECO mode to Online mode.Operating temperature:0℃-50℃;0~40℃ full load ;40~50℃ derating(VA&W derating3%/1℃),Relative humidity:20%~90%(No condensation),Its dimensions was 438*600*85.5 mm (2U)mm (W*D*H),Net weight:28.5kg,Audio noise was <50dB @ Distance of 1 meter,Operating altitude was 0~3000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output,Execution standards:Safety:IEC/EN 62040-1;(EMC):IEC/EN 62040-2:C1;Performance:IEC/EN62040-3.Product Certification:TLC,CE,CQC.Communication and monitoring include Standard configuration includes USB, RS232, remote power on/off, smart slot, dry contacts, RJ45 (cloud connection), WiFi (optional),Optional Accessories include NMC card (network monitoring card) can be selected; CMC card (Modbus monitoring card); EMP (Temperature and Humidity Acquisition Module); AS400 card (dry connection point card); SPCC_N (Cloud Connection Network Card); WLANdongle (Cloud Connection Card Wifi Module) (requires the purchase of a smart card slot),EPO(optional):N/A,Parallel redundancy(optional):N/A,Software:Winpower,Warranty:5 years .Application scenarios include IT and network equipment; Small servers and workstations; Switches and monitoring devices; ATM ATM machine; Automatic Ticket Machine; Power and railway signal systems; SCADA system; Office computer; printer; Scanner; POS cash register; refueller

Product Features

  • Dual conversion online architecture: fully digital control, zero switching between mains and lithium batteries, output pure sine wave, ensuring zero interruption of equipment.
  • Lithium ion battery is highly efficient and energy-saving: The cycle life of lithium-ion batteries is over 2000 times, the volume is reduced by 30%, and it supports 6A fast charging and battery free startup.
  • High power density output: output power factor PF=1, load capacity increased by 40%, suitable for high-density load scenarios.
  • Ultra wide voltage adaptability: Input voltage 110-300VAC, compatible with harsh power grids and generators, ensuring stable power supply.
  • Intelligent ECO mode: The grid stability efficiency reaches 98%, saving energy and reducing consumption, and lowering operating costs.
  • LoT remote management: standard wired Ethernet, optional wireless module, supports real-time monitoring and fault alarm on mobile devices.
  • Multiple communication interfaces: supports RPO dry contacts USB、RS232, Adapt to centralized control of multi protocol devices.
  • Industrial grade protection design: Silent operation, wide temperature range (-20℃~50℃),suitable for harsh industrial environments.

Application Scenarios

  • IT and network equipment; Small servers and workstations; Switches and monitoring devices; ATM ATM machine; Automatic Ticket Machine; Power and railway signal systems; SCADA system; Office computer; printer; Scanner; POS cash register; refueller

Product Parameters

  • Brand:SANTAK
  • Product-type:Uninterruptible power system
  • Series:SANTAK PT3000 LoT series PT1-3K
  • Topology:Online (dual conversion)
  • Backup type:Standard model
  • Installation method:Vertical/Tower/Horizontal/rack mounted
  • System:Single phase input, single-phase output
  • Product Category:Lithium battery UPS
  • Model:PT3KSLI-i
  • Load power(max):3000VA/3000W
  • Input method:Single phase two-wire+grounded (L+N+PE)
  • Rated voltage:(200Vac/208Vac/220Vac/230Vac/240Vac (defult220Vac)
  • Input Voltage:160-300V 100%load, 110-160V Linear derating to50%load
  • Input frequency:45 Hz– 55 Hz(50Hz)/54 Hz – 66 Hz(60Hz)
  • THDI:< 5% Nonlinear full load
  • Input power factor:≥ 0.99
  • Bypass voltage:187VAC~264VAC
  • Output voltage:220Vdefult(200/208/220/230/240 VAC optional)
  • Output accuracy:± 1 %
  • Output Connection:Main output (1 x IEC C19 + 4 x IEC C13) Partition control output ( 4 x IEC C13)
  • Output frequency range (mains mode):50Hz/60Hz adaptive
  • Output frequency range (battery mode):50Hz/60Hz adaptive
  • Peak output current ratio:3:1
  • Output waveform distortion:<1%(linear load;<5%(Nonlinear load)
  • Output power factor:PF = 1
  • Output waveform:Pure sine output
  • Overload capacity (mains 25 ℃, output power factor 0.8):100%150% 500ms
  • Efficiency:online mode:Up to 93%;ECO mode:Up to 97%
  • Battery voltage × number of batteries:76.8VDC/No built-in battery
  • EBM mode:PTLB07228
  • EBM max number:4 PCS Max
  • Hot swappable battery:Y
  • Battery charging temperature compensation:Y
  • Conversion time (mains<>battery):0ms@Online mode to Battery mode; 4ms @Online mode to Bypass mode; 10ms @ECO mode to Online mode
  • Display:LCD+LED can digitally display load/power/input/output parameters, text and graphical display of operating modes
  • Battery backup time (25 ℃):1*EBM,Half load ≤60min;full load ≥30min
  • Battery charging time:3.8hour recharge to 90%
  • Rack mounted installation height:2U
  • Dimensions(W×D×H)(mm):438*600*85.5 mm (2U)
  • Net weight(kg):11.0kg
  • EBM Dimensions(W×D×H)(mm):438*600*85.5 mm (2U)
  • EBM Net weight(kg):28.5kg
  • Operating temperature:0℃-50℃;0~40℃ full load ;40~50℃ derating(VA&W derating3%/1℃)
  • Storage temperature:-25℃~55℃
  • Relative humidity:20%~90%(No condensation)
  • Audio noise (at a distance of 1 meter):<50dB @ Distance of 1 meter
  • Protection level:IP20
  • Operating altitude:0~3000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output
  • Execution standards:Safety:IEC/EN 62040-1;(EMC):IEC/EN 62040-2:C1;Performance:IEC/EN62040-3
  • Product Certification:TLC,CE,CQC
  • Communication and monitoring:Standard configuration includes USB, RS232, remote power on/off, smart slot, dry contacts, RJ45 (cloud connection), WiFi (optional)
  • Optional Accessories:NMC card (network monitoring card) can be selected; CMC card (Modbus monitoring card); EMP (Temperature and Humidity Acquisition Module); AS400 card (dry connection point card); SPCC_N (Cloud Connection Network Card); WLANdongle (Cloud Connection Card Wifi Module) (requires the purchase of a smart card slot)
  • EPO(optional):N/A
  • Parallel redundancy(optional):N/A
  • Software:Winpower
  • Warranty:5 years
  • Note-1:When the altitude is between 3000 meters and 1000 meters, the load rating needs to be reduced. When the ambient temperature is above 25 ℃, the load rating should be reduced by 1% for every 100 meters increase in altitude above 1000 meters.
  • Note-2:Warning: This product is a C2 class UPS and may require installation restrictions or additional measures to suppress RF interference when used in residential areas.
Telephone
4001177032
email
19710409880@139.com
wechat
wechat
Loading...