Product details

santak emergency supply PT6K,is a kind of Uninterruptible power systemproducts.Its topology was High frequency UPS,Online (dual conversion),Standard model (with built-in battery),Single phase input, single-phase output,Its installation method was Vertical/Tower/Horizontal/rack mounted,It belongs to SANTAK PT3000 series PT1-20K.Its rated capacity and maximum load power was 6kVA/6kW,Input method was Single phase two-wire+grounded (L+N+PE).Rated voltage was 208/220/230/240VAC.Input Voltage was 110VAC-275VAC,Input frequency was 40~70Hz,THDI was < 3% Nonlinear full load,Input power factor was ≥ 0.99,Bypass voltage was 187VAC~264VAC,Output voltage was 208/220/230/240VAC,Output accuracy was ± 1 %,Output Connection was IEC C13*2+Output terminal block,Output frequency range (mains mode) was 46-54Hz,Output frequency range (battery mode) was 50/60Hz±0.1Hz,Peak output current ratio was 3:1,Output waveform distortion was <1%(linear load;<5%(Nonlinear load),Output power factor was PF = 1,Output waveform was Pure sine output,Overload capacity (mains 25 ℃, output power factor 0.8):105%-125%Load, switch to bypass operation after 10 minutes;125%-150%Load, switch to bypass after 30 seconds; More than 150% load, switch to bypass after 0.5 seconds,Efficiency:online mode:Up to 95%;ECO mode:Up to 98%,Battery voltage × number of batteries:192VDC/16*12V7AH,EBM mode was PTB7161,EBM max number was 4 PCS Max,Hot swappable battery:Y,Battery charging temperature compensation:Y,Battery backup time (25 ℃) was Half load ≤11min;full load ≥4min,Battery charging time was 3 hour recharge to 90%,Display:LCD+LED can digitally display load/power/input/output parameters, text and graphical display of operating modes,Rack mounted installation height:2U,Protection level:IP20,Conversion time (mains<>battery) was 0ms(Online mode to Battery mode);<0ms(Battery mode to Bypass mode).Operating temperature:0℃-50℃;0~40℃ full load ;40~50℃ derating(VA&W derating3%/1℃),Relative humidity:20%~90%(No condensation),Its dimensions was 438*573*85.5 mm (2U)mm (W*D*H),Net weight:46.3,Audio noise was <50dB @ Distance of 1 meter,Operating altitude was 0~3000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output,Execution standards:Safety:IEC/EN 62040-1;(EMC):IEC/EN 62040-2:C3;Performance:IEC/EN62040-3.Product Certification:TLC/CE/CQCenergy conservation.Communication and monitoring include Standard configuration includes USB/RS232/RPO/COO, smart slot, and dry node,Optional Accessories include NMC card (network monitoring card) can be selected; CMC card (Modbus monitoring card); EMP (Temperature and Humidity Acquisition Module); AS400 card (dry connection point card); SPCC_N (Cloud Connection Network Card); WLANdongle (Cloud Connection Card Wifi Module) (requires the purchase of a smart card slot),EPO(optional):emergency shutdown,Parallel redundancy(optional):Maximum of 3 parallel machines,Software:Winpower,Warranty:3 years .Application scenarios include Small and medium-sized enterprises; Large enterprise branch offices; Small scale data centers such as bank branches; Switch; NAS storage; Network server; VoIP; Communication equipment; Automated equipment; Office PC terminal; Medical biochemistry laboratory instruments and equipment, etc

Product Features

  • Efficient dual conversion architecture: Online mode efficiency of 95% -96%, output PF=1, load capacity increased by 30%, significant energy saving and consumption reduction.
  • Full scenario power purification: solves 11 types of power problems such as power outages and harmonics, outputs pure sine waves, and ensures zero interruption of equipment.
  • Flexible input/output configuration: supports four modes including three in single out and three in three out, adapting to global power grids and multi scenario needs.
  • Intelligent battery management: 16-40 batteries can be adjusted, and the charging current can be flexibly set between 1-13A to extend battery life and endurance.
  • Adaptation to harsh environments: Three proof coated circuit board, stable operation at 50 ℃ high temperature, passed seismic and industrial reliability tests.
  • Intelligent load grading: prioritize ensuring power supply for critical equipment, and extend the backup time for core loads in battery mode.
  • Human computer interaction optimization: touch LCD screen+multi protocol interface (USB/RS232/dry contacts), supporting remote monitoring and virtualization platform integration.
  • Compact and highly compatible design: Rack mounted with a height of only 2U and a depth of<600mm, compatible with standard cabinets, saving deployment space.

Application Scenarios

  • Small and medium-sized enterprises; Large enterprise branch offices; Small scale data centers such as bank branches; Switch; NAS storage; Network server; VoIP; Communication equipment; Automated equipment; Office PC terminal; Medical biochemistry laboratory instruments and equipment, etc

Product Parameters

  • Brand:SANTAK
  • Product-type:Uninterruptible power system
  • Series:SANTAK PT3000 series PT1-20K
  • Topology:Online (dual conversion)
  • Backup type:Standard model (with built-in battery)
  • Installation method:Vertical/Tower/Horizontal/rack mounted
  • System:Single phase input, single-phase output
  • Product Category:High frequency UPS
  • Model:PT6K
  • Load power(max):6kVA/6kW
  • Input method:Single phase two-wire+grounded (L+N+PE)
  • Rated voltage:208/220/230/240VAC
  • Input Voltage:110VAC-275VAC
  • Input frequency:40~70Hz
  • THDI:< 3% Nonlinear full load
  • Input power factor:≥ 0.99
  • Bypass voltage:187VAC~264VAC
  • Output voltage:208/220/230/240VAC
  • Output accuracy:± 1 %
  • Output Connection:IEC C13*2+Output terminal block
  • Output frequency range (mains mode):46-54Hz
  • Output frequency range (battery mode):50/60Hz±0.1Hz
  • Peak output current ratio:3:1
  • Output waveform distortion:<1%(linear load;<5%(Nonlinear load)
  • Output power factor:PF = 1
  • Output waveform:Pure sine output
  • Overload capacity (mains 25 ℃, output power factor 0.8):105%-125%Load, switch to bypass operation after 10 minutes;125%-150%Load, switch to bypass after 30 seconds; More than 150% load, switch to bypass after 0.5 seconds
  • Efficiency:online mode:Up to 95%;ECO mode:Up to 98%
  • Battery voltage × number of batteries:192VDC/16*12V7AH
  • EBM mode:PTB7161
  • EBM max number:4 PCS Max
  • Hot swappable battery:Y
  • Battery charging temperature compensation:Y
  • Conversion time (mains<>battery):0ms(Online mode to Battery mode);<0ms(Battery mode to Bypass mode)
  • Display:LCD+LED can digitally display load/power/input/output parameters, text and graphical display of operating modes
  • Battery backup time (25 ℃):Half load ≤11min;full load ≥4min
  • Battery charging time:3 hour recharge to 90%
  • Rack mounted installation height:2U
  • Dimensions(W×D×H)(mm):438*573*85.5 mm (2U)
  • Net weight(kg):14
  • EBM Dimensions(W×D×H)(mm):438*589*129 mm (3U)
  • EBM Net weight(kg):46.3
  • Operating temperature:0℃-50℃;0~40℃ full load ;40~50℃ derating(VA&W derating3%/1℃)
  • Storage temperature:-25℃~55℃
  • Relative humidity:20%~90%(No condensation)
  • Audio noise (at a distance of 1 meter):<50dB @ Distance of 1 meter
  • Protection level:IP20
  • Operating altitude:0~3000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output
  • Execution standards:Safety:IEC/EN 62040-1;(EMC):IEC/EN 62040-2:C3;Performance:IEC/EN62040-3
  • Product Certification:TLC/CE/CQCenergy conservation
  • Communication and monitoring:Standard configuration includes USB/RS232/RPO/COO, smart slot, and dry node
  • Optional Accessories:NMC card (network monitoring card) can be selected; CMC card (Modbus monitoring card); EMP (Temperature and Humidity Acquisition Module); AS400 card (dry connection point card); SPCC_N (Cloud Connection Network Card); WLANdongle (Cloud Connection Card Wifi Module) (requires the purchase of a smart card slot)
  • EPO(optional):emergency shutdown
  • Parallel redundancy(optional):Maximum of 3 parallel machines
  • Software:Winpower
  • Warranty:3 years
  • Note-1:When the distance between the load and the parallel UPS is less than 10 meters, the length difference of the input/output lines between each UPS in the parallel system must be less than 20%.