SANTAK UPS MT500 500VA/300W (voltage regulator+UPS) 100VA (voltage regulator)
SANTAK UPS,MT500,500VA/300W (voltage regulator+UPS) 100VA (voltage regulator),Standby or Off-line,apply for Workstations, network servers, enterprise home PC computers, router modems, cash register POS machines, printers, scanners, home entertainment systems, ATM machines, advertising machines
Buy Now
- Telephone:4001177032
- Email:19710409880@139.com
Product details
SANTAK UPS MT500,is a kind of Uninterruptible power systemproducts.Its topology was Standby or Off-lineStandard model (with built-in battery),Installation method was Vertical/Horizontal/Rack mounted,belongs to SANTAK MT Series.Its rated capacity and maximum load power was 500VA/300W (voltage regulator+UPS) 100VA (voltage regulator),Load type include Workstations, networks, and peripheral devices such as monitors.Input voltage was 173-273+/-7Vrms (standard mode) 148-295+/-7Vrms (super mode),Input frequency was 50±10HZ,Output voltage(mains power mode) was 200-240Vrms ± 4% (standard mode) 170-260Vrms ± 4% (super mode),Output frequency(mains power mode) Synchronize with mains power (sine wave),Battery voltage × number of batteries:12V/1*12V7.2AH,Battery backup time was ≥ 3.5 minutes (full load) ≥ 10 minutes (half load),Battery charging time was ≤10Hour,Short Circuit Protection in mains mode:Overcurrent circuit breaker opens and short circuit alarm (red light on, buzzer beeps continuously), no output,Short Circuit Protection in battery mode:Short circuit alarm (red light on, buzzer beeping), no output,Overload protection in mains mode:Load capacity: 100% to 120%, continuous operation; Load capacity: ≥ 120%, power off after 1 minute of alarm; Load capacity: ≥ 150%, immediately cut off output,Conversion time (mains<>battery) was ≤10Hour.Operating temperature was 0℃-40℃,Relative humidity was 20% - 90%,无冷凝,Dimensions was 198*317*79mm (W*D*H),Net weight was 5.0kg/5.5kg,Audio noise (at a distance of 1 meter) was ≤50dB.Safety regulations:GB4943;GB7260.2/IEC62040-2CLASSA;IEC 61000-4-2 Contact Discharge: Level 4 Air Discharge: Level 4;IEC 61000-4-3 Level 3;IEC 61000-4-4 Level 4;IEC 61000-4-5 Level 4;IEC 61643-11.Application scenarios include:Workstations, network servers, enterprise home PC computers, router modems, cash register POS machines, printers, scanners, home entertainment systems, ATM machines, advertising machines
Product Features
- Multi form flexible deployment: vertical/horizontal/rack mounted three in one installation, suitable for computer rooms, cabinets, and compact space scenarios.
- Intelligent remote management: Configure intelligent slots, support USB/Webpower/EMD expansion, achieve remote monitoring and networked management.
- Super power grid adaptation: Input voltage range of 148-295VAC (super power mode), compatible with harsh power grids and generator power supply.
- Multiple battery life options: Standard/Extended/Long lasting models are available, with the Long lasting model supporting an external battery pack and allowing for flexible extension of backup time.
- Dual power protection: independent voltage regulation output socket+RJ45/RJ11 surge protection interface, ensuring the safety of peripherals and network equipment.
- Efficient charging technology: 6A high current intelligent charging module, 10 hour fast recharge, supports unmanned scenarios.
- Strict safety certification: Through international standards such as GB4943 and IEC62040, electromagnetic compatibility and reliability are double guaranteed.
- Compact high-power design: The 1000VA model weighs only 43kg and has a half load range of ≥ 10 minutes, balancing high-density deployment and long-term power supply requirements.
Application Scenarios
- Workstations, network servers, enterprise home PC computers, router modems, cash register POS machines, printers, scanners, home entertainment systems, ATM machines, advertising machines
Product Parameters
- Brand:SANTAK
- Product-type:Uninterruptible power system
- Series:SANTAK MT Series
- Topology:Standby or Off-line
- Backup type:Standard model (with built-in battery)
- Installation method:Vertical/Horizontal/Rack mounted
- Model:MT500
- Load power(max):500VA/300W (voltage regulator+UPS) 100VA (voltage regulator)
- Load type:Workstations, networks, and peripheral devices such as monitors
- Input voltage:173-273+/-7Vrms (standard mode) 148-295+/-7Vrms (super mode)
- Input frequency:50±10HZ
- Output voltage(mains power mode):200-240Vrms ± 4% (standard mode) 170-260Vrms ± 4% (super mode)
- Output frequency(mains power mode):Synchronize with mains power (sine wave)
- Output voltage(Battery mode):220×(1±10%)VAC(Quasi square wave)
- Output frequency(Battery mode):50Hz±1Hz
- Battery voltage × number of batteries:12V/1*12V7.2AH
- Conversion time (mains<>battery):<10ms
- Battery backup time:≥ 3.5 minutes (full load) ≥ 10 minutes (half load)
- Battery charging time:≤10Hour
- Short Circuit Protection in mains mode:Overcurrent circuit breaker opens and short circuit alarm (red light on, buzzer beeps continuously), no output
- Short Circuit Protection in battery mode:Short circuit alarm (red light on, buzzer beeping), no output
- Overload protection in mains mode:Load capacity: 100% to 120%, continuous operation; Load capacity: ≥ 120%, power off after 1 minute of alarm; Load capacity: ≥ 150%, immediately cut off output
- Overload protection in battery mode:Load capacity: 100%~120%, cut off output after 3 minutes of alarm; Load capacity: ≥ 120%, immediately cut off output
- Overload protection (stabilized output):Overcurrent circuit breaker tripped, no output
- Dimensions(W×D×H)(mm):198*317*79
- Net weight(kg):5.0kg/5.5kg
- Operating temperature:0℃-40℃
- Storage temperature:-15℃-50℃
- Relative humidity:20% - 90%,无冷凝
- Audio noise (at a distance of 1 meter):≤50dB
- Safety regulations:GB4943
- EMC:GB7260.2/IEC62040-2CLASSA
- EMS(ESD):IEC 61000-4-2 Contact Discharge: Level 4 Air Discharge: Level 4
- EMS(RS):IEC 61000-4-3 Level 3
- EMS(EFT):IEC 61000-4-4 Level 4
- EMS(SURGE):IEC 61000-4-5 Level 4
- EMS (SPD):IEC 61643-11
- Note-1:Warning: This product is a C2 class UPS and may require installation restrictions or additional facilities to suppress RF interference when used in residential areas.
- Note-2:Attention: If the UPS is used at an altitude of over 1000m, it must use a decreasing rated output