SANTAK,Digital Twin Simulation System uninterruptible power system,C10K,9000W/10000VA,Online (dual conversion),Standard model (with built-in battery),Rated input voltage220VAC,input frequency40Hz-70Hz,applyIT and network equipment; Small servers and workstations; Switches and monitoring devices; ATM ATM machine; Automatic Ticket Machine; Power and railway signal systems; SCADA system; Office computer; printer; Scanner; POS cash register; refueller
Buy Now
- Telephone:4001177032
- Email:19710409880@139.com
Product details
SANTAK Digital Twin Simulation System uninterruptible power system C10K,is a kind of Uninterruptible power systemproducts.Its topology was Online (dual conversion),Standard model (with built-in battery),Single phase input, single-phase output,Installation method was Vertical/Tower,belongs to SANTAK CASTLE series C1-10K.Its rated capacity and maximum load power was 9000W/10000VA,Input method was Single phase two-wire+grounded (L+N+PE).Rated voltage was 220VAC.Input Voltage was 120~275VAC,Input frequency was 40Hz-70Hz,THDI:< 5% Nonlinear full load,Input power factor was ≥ 0.99,Bypass voltage was 187VAC~264VAC,Output voltage was 220VAC,Output accuracy was ±1%,Output Connection was Output terminal block,Output frequency range (mains mode) was 46-54Hz,Output frequency range (battery mode) was 50/60Hz±0.2Hz,Peak output current ratio was 3:1,Output waveform distortion was <2%(Linear Load);<4%(Nonlinear load),Output power factor was 0.9,Output waveform was Pure sine output,Overload capacity (mains 25 ℃, output power factor 0.8):105%~125%,After 10 minutes at room temperature (0-30 degrees Celsius), switch to bypass,After 1 minute at high temperature (30-40 degrees Celsius), switch to bypass;125%~150%,30S switch to bypass;>150%,0.5S switch to bypass,Efficiency:AC power mode:Up to 94%;ECO:Up to 98%,Battery voltage × number of batteries:180VDC/15*12V7AH,Battery backup time (25 ℃) was full load≥3min,Battery charging time was 7 Hour recharge to 90%,Display:LCD+LED can digitally display load/power/input/output parameters, text and graphical display of operating modes,Rack mounted installation height:7 Hour recharge to 90%,Protection level:IP20,Conversion time (mains<>battery):0ms(AC power mode-Battery mode);<4ms(AC power mode-Bypass mode).Operating temperature was 0-40℃,Relative humidity was 20%~90%(No condensation),Dimensions was 248×500×565mm (W*D*H),Net weight was 62KG,Audio noise (at a distance of 1 meter) was <50dB @ distance 1 m,Operating altitude was <1000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output,Execution standards include:IEC61000, IEC62040, GB7260,GB4943.Product Certification:TLC/ Energy saving certification.Communication and monitoring was Standard configuration RS232,Optional Accessories include:NMC card (network monitoring card) can be selected; CMC card (Modbus monitoring card); EMP (Temperature and Humidity Acquisition Module); AS400 card (dry connection point card); SPCC_N (Cloud Connection Network Card); WLANdongle (Cloud Connection Card Wifi Module) (requires the purchase of a smart card slot),EPO(optional):emergency shutdown,Parallel redundancy(optional):Maximum of 3 parallel machines (optional); And each UPS must be independently equipped with a battery pack,Software was Winpower,Warranty:3Years.Application scenarios include:IT and network equipment; Small servers and workstations; Switches and monitoring devices; ATM ATM machine; Automatic Ticket Machine; Power and railway signal systems; SCADA system; Office computer; printer; Scanner; POS cash register; refueller
Product Features
- Full scenario online protection: Dual conversion online design, accurately solving 9 types of power problems, ensuring zero power outage switching of equipment.
- Super environmental adaptability: Input voltage of 160-280VAC, compatible with generators, supporting extreme environments such as high altitude, humid heat, and power grid fluctuations.
- Efficient and energy-saving design: C6-10kVA full load efficiency of 94%, ECO mode efficiency of 98%, power factor of 0.9, significant energy saving and consumption reduction.
- Intelligent expansion management: supports optional NMC network cards, EMP temperature and humidity modules, etc., to achieve remote monitoring and environmental data collection.
- Silent and low-noise operation: The noise level of C6-10kVA is as low as 47dB, suitable for office and precision equipment scenarios, reducing environmental interference.
- High density compact structure: Innovative heat dissipation design reduces volume by 20%, increases power density, and saves data center space.
- Flexible battery life configuration: Supports external battery packs to extend backup time, and long-lasting models are suitable for the needs of areas with power shortages.
- Strict safety certification: compliant with GB4943 and IEC62040 standards, passed the EU environmental directive, ensuring long-term stable operation.
Application Scenarios
- IT and network equipment; Small servers and workstations; Switches and monitoring devices; ATM ATM machine; Automatic Ticket Machine; Power and railway signal systems; SCADA system; Office computer; printer; Scanner; POS cash register; refueller
Product Parameters
- Brand:SANTAK
- Product-type:Uninterruptible power system
- Series:SANTAK CASTLE series C1-10K
- Topology:Online (dual conversion)
- Backup type:Standard model (with built-in battery)
- Installation method:Vertical/Tower
- System:Single phase input, single-phase output
- Model:C10K
- Load power(max):9000W/10000VA
- Input method:Single phase two-wire+grounded (L+N+PE)
- Rated voltage:220VAC
- Input Voltage:120~275VAC
- Input frequency:40Hz-70Hz
- THDI:< 5% Nonlinear full load
- Input power factor:≥ 0.99
- Bypass voltage:187VAC~264VAC
- Output voltage:220VAC
- Output accuracy:±1%
- Output Connection:Output terminal block
- Output frequency range (mains mode):46-54Hz
- Output frequency range (battery mode):50/60Hz±0.2Hz
- Peak output current ratio:3:1
- Output waveform distortion:<2%(Linear Load);<4%(Nonlinear load)
- Output power factor:0.9
- Output waveform:Pure sine output
- Overload capacity (mains 25 ℃, output power factor 0.8):105%~125%,After 10 minutes at room temperature (0-30 degrees Celsius), switch to bypass,After 1 minute at high temperature (30-40 degrees Celsius), switch to bypass;125%~150%,30S switch to bypass;>150%,0.5S switch to bypass
- Efficiency:AC power mode:Up to 94%;ECO:Up to 98%
- Battery voltage × number of batteries:180VDC/15*12V7AH
- Conversion time (mains<>battery):0ms(AC power mode-Battery mode);<4ms(AC power mode-Bypass mode)
- Display:LCD+LED can digitally display load/power/input/output parameters, text and graphical display of operating modes
- Battery backup time (25 ℃):full load≥3min
- Battery charging time:7 Hour recharge to 90%
- Rack mounted installation height:N/A
- Dimensions(W×D×H)(mm):248×500×565
- Net weight(kg):62
- Operating temperature:0-40℃
- Storage temperature:-25℃~55℃
- Relative humidity:20%~90%(No condensation)
- Audio noise (at a distance of 1 meter):<50dB @ distance 1 m
- Protection level:IP20
- Operating altitude:<1000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output
- Execution standards:IEC61000, IEC62040, GB7260,GB4943
- Product Certification:TLC/ Energy saving certification
- Communication and monitoring:Standard configuration RS232
- Optional Accessories:NMC card (network monitoring card) can be selected; CMC card (Modbus monitoring card); EMP (Temperature and Humidity Acquisition Module); AS400 card (dry connection point card); SPCC_N (Cloud Connection Network Card); WLANdongle (Cloud Connection Card Wifi Module) (requires the purchase of a smart card slot)
- EPO(optional):emergency shutdown
- Parallel redundancy(optional):Maximum of 3 parallel machines (optional); And each UPS must be independently equipped with a battery pack
- Software:Winpower
- Warranty:3Years
- Note-1:Note: It is recommended that the UPS output line should not exceed 10m, and the external communication line, parallel line, and temperature detection line should not exceed 3m. Otherwise, installation restrictions or additional measures may need to be taken to suppress interference.
- Note-2:Warning: This product is a C2 class UPS and may require installation restrictions or additional measures to suppress RF interference when used in residential areas.