Product details

SANTAK Automated production line control cabinet uninterruptible power system C6KS Rack,is a kind of Uninterruptible power systemproducts.Its topology was Online (dual conversion),Long lasting model (external battery),Single phase input, single-phase output,Installation method was Horizontal/rack mounted,belongs to SANTAK CASTLE series C1-10K.Its rated capacity and maximum load power was 6000VA/5400W,Input method was Single phase two-wire+grounded (L+N+PE).Rated voltage was 208/220/230/240VAC.Input Voltage was 110-300VAC,Input frequency was 40Hz-70Hz,THDI:< 5% Nonlinear full load,Input power factor was ≥ 0.99,Bypass voltage was 187VAC~264VAC,Output voltage was 220VAC,Output accuracy was ±1%,Output Connection was IEC C13*2+Output terminal block,Output frequency range (mains mode) was 46-54Hz,Output frequency range (battery mode) was 50/60Hz±0.1Hz,Peak output current ratio was 3:1,Output waveform distortion was <1%(Linear Load);<4%(Nonlinear load),Output power factor was 0.9,Output waveform was Pure sine output,Overload capacity (mains 25 ℃, output power factor 0.8):105%~125%,After 10 minutes at room temperature (0-30 degrees Celsius), switch to bypass,After 1 minute at high temperature (30-40 degrees Celsius), switch to bypass;125%~150%,30S switch to bypass;>150%,0.5S switch to bypass,Efficiency:AC power mode:Up to 95%;ECO:Up to 98%,Battery voltage × number of batteries:192VDC/Depends on user needs and configuration,Battery backup time (25 ℃) was Depending on user needs and configuration, the battery life can be configured from 30 minutes to 8 hours,Battery charging time was Depends on the capacity of the external battery pack (long-lasting type),Display:LCD+LED can digitally display load/power/input/output parameters, text and graphical display of operating modes,Rack mounted installation height:Depends on the capacity of the external battery pack (long-lasting type),Protection level:IP20,Conversion time (mains<>battery):0ms(AC power mode-Battery mode);<4ms(AC power mode-Bypass mode).Operating temperature was 0°C ~ 50℃,Relative humidity was 0 ~ 95% (No condensation),Dimensions was 438*571*86.3mm (W*D*H),Net weight was 13.6KG,Audio noise (at a distance of 1 meter) was ≤ 45dB@ distance 1 m,Operating altitude was <1000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output,Execution standards include:IEC61000, IEC62040, GB7260,GB4943.Product Certification:TLC/ Energy saving certification/CE.Communication and monitoring was Standard configuration RS232/USB/programmable dry node interface -1 input+1 output,Optional Accessories include:NMC card (network monitoring card) can be selected; CMC card (Modbus monitoring card); EMP (Temperature and Humidity Acquisition Module); AS400 card (dry connection point card); SPCC_N (Cloud Connection Network Card); WLANdongle (Cloud Connection Card Wifi Module) (requires the purchase of a smart card slot),EPO(optional):emergency shutdown,Parallel redundancy(optional):Maximum of 3 parallel machines (optional); And each UPS must be independently equipped with a battery pack,Software was Winpower,Warranty:3Years.Application scenarios include:IT and network equipment; Small servers and workstations; Switches and monitoring devices; ATM ATM machine; Automatic Ticket Machine; Power and railway signal systems; SCADA system; Office computer; printer; Scanner; POS cash register; refueller

Product Features

  • Efficient dual conversion architecture: Online mode efficiency of 95%, output pure sine wave, zero switching ensures zero interruption of equipment.
  • Ultra wide power grid adaptation: Input voltage 110-300VAC, compatible with generators, 40-70Hz broadband input, suitable for harsh power environments.
  • Intelligent remote management: supports APP monitoring, MODBUS protocol, and virtualization platform to achieve fault alarm and centralized control.
  • Flexible battery configuration: 1-3kVA supports 12 hour external battery, 6-10kVA adjustable 16-20 batteries, 12A fast charging reduces recharge time.
  • High density compact design: The 10kVA model has a height of only 2U and a depth of<600mm, saving cabinet space and supporting redundant parallel expansion.
  • Green energy-saving certification: Input power factor>0.99, harmonics<3%, passed CQC, Theil certification and EU environmental standards.
  • Silent and efficient heat dissipation: 40 decibel low noise mode, stable operation in a high temperature environment of 50 ℃, suitable for library and precision equipment scenarios.
  • Full scenario power purification: CVCF constant voltage and frequency output, ± 1% voltage accuracy, suitable for industrial control and highly sensitive instrument equipment.

Application Scenarios

  • IT and network equipment; Small servers and workstations; Switches and monitoring devices; ATM ATM machine; Automatic Ticket Machine; Power and railway signal systems; SCADA system; Office computer; printer; Scanner; POS cash register; refueller

Product Parameters

  • Brand:SANTAK
  • Product-type:Uninterruptible power system
  • Series:SANTAK CASTLE series C1-10K
  • Topology:Online (dual conversion)
  • Backup type:Long lasting model (external battery)
  • Installation method:Horizontal/rack mounted
  • System:Single phase input, single-phase output
  • Model:C6KS Rack
  • Load power(max):6000VA/5400W
  • Input method:Single phase two-wire+grounded (L+N+PE)
  • Rated voltage:208/220/230/240VAC
  • Input Voltage:110-300VAC
  • Input frequency:40Hz-70Hz
  • THDI:< 5% Nonlinear full load
  • Input power factor:≥ 0.99
  • Bypass voltage:187VAC~264VAC
  • Output voltage:220VAC
  • Output accuracy:±1%
  • Output Connection:IEC C13*2+Output terminal block
  • Output frequency range (mains mode):46-54Hz
  • Output frequency range (battery mode):50/60Hz±0.1Hz
  • Peak output current ratio:3:1
  • Output waveform distortion:<1%(Linear Load);<4%(Nonlinear load)
  • Output power factor:0.9
  • Output waveform:Pure sine output
  • Overload capacity (mains 25 ℃, output power factor 0.8):105%~125%,After 10 minutes at room temperature (0-30 degrees Celsius), switch to bypass,After 1 minute at high temperature (30-40 degrees Celsius), switch to bypass;125%~150%,30S switch to bypass;>150%,0.5S switch to bypass
  • Efficiency:AC power mode:Up to 95%;ECO:Up to 98%
  • Battery voltage × number of batteries:192VDC/Depends on user needs and configuration
  • Conversion time (mains<>battery):0ms(AC power mode-Battery mode);<4ms(AC power mode-Bypass mode)
  • Display:LCD+LED can digitally display load/power/input/output parameters, text and graphical display of operating modes
  • Battery backup time (25 ℃):Depending on user needs and configuration, the battery life can be configured from 30 minutes to 8 hours
  • Battery charging time:Depends on the capacity of the external battery pack (long-lasting type)
  • Rack mounted installation height:2U
  • Dimensions(W×D×H)(mm):438*571*86.3
  • Net weight(kg):13.6
  • Operating temperature:0°C ~ 50℃
  • Storage temperature:-25℃~55℃
  • Relative humidity:0 ~ 95% (No condensation)
  • Audio noise (at a distance of 1 meter):≤ 45dB@ distance 1 m
  • Protection level:IP20
  • Operating altitude:<1000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output
  • Execution standards:IEC61000, IEC62040, GB7260,GB4943
  • Product Certification:TLC/ Energy saving certification/CE
  • Communication and monitoring:Standard configuration RS232/USB/programmable dry node interface -1 input+1 output
  • Optional Accessories:NMC card (network monitoring card) can be selected; CMC card (Modbus monitoring card); EMP (Temperature and Humidity Acquisition Module); AS400 card (dry connection point card); SPCC_N (Cloud Connection Network Card); WLANdongle (Cloud Connection Card Wifi Module) (requires the purchase of a smart card slot)
  • EPO(optional):emergency shutdown
  • Parallel redundancy(optional):Maximum of 3 parallel machines (optional); And each UPS must be independently equipped with a battery pack
  • Software:Winpower
  • Warranty:3Years
  • Note-1:Note: It is recommended that the UPS output line should not exceed 10m, and the external communication line, parallel line, and temperature detection line should not exceed 3m. Otherwise, installation restrictions or additional measures may need to be taken to suppress interference.
  • Note-2:Warning: This product is a C2 class UPS and may require installation restrictions or additional measures to suppress RF interference when used in residential areas.