Industrial critical power100kVA/90kWThree phase input/single-phase outputDC384V:Built in output isolation transformerBattery direct hanging DC bus
Industrial critical power,SIU100K-316PFXC,100kVA/90kW,Three phase input/single-phase output,Rated input voltagethree phase:380/400/415VAC,6 pulse add 5th filter:≤10%,DC384V:Built in output isolation transformer,apply toElectric power industry, DCS discrete control system, generator transformer protection system, desulfurization control system; Petroleum and petrochemicals, oil and gas collection systems, pipeline transmission systems, oil and gas storage and transportation systems, refining systems; Steel and coal manufacturing industry, DCS distributed control system, industrial computer and display screen, PLC control system; Rail transportation industry, vehicle/airport ground power system, integrated security system, communication signal system, integrated monitoring system; Light/Heavy Industry
Buy Now
- Telephone:4001177032
- Email:19710409880@139.com
Product details
SANTAK Industrial critical power SIU100K-316PFXC,is a kind of Uninterruptible power systemproducts..Its topology wasOnline (dual conversion),Long lasting model (external battery),Three phase input/single-phase output,Industrial UPS,It belongs to SANTAK Industrial UPS SIU series (10-200KVA).Its rated capacity and maximum load power was 100kVA/90kW,Type of power system was TN-S, TN-C, TN-C-S, TT, IT,Input/output voltage phase was Three phase input/single-phase output,Input method was Three phase without N line(L1/L2/L3/G).Rated voltage was three phase:380/400/415VAC.Input Voltage was 285VAC-498VAC,Input frequency was Rated 50/60Hz;Frequency range:45-66Hz,THDI was 6 pulse add 5th filter:≤10%,Input power factor was 6 pulse add 5th filter:≥0.92,Bypass voltage was single phase:220/230/240VAC,Default 220VAC,Bypass input voltage range was Default upper limit+20%,Default lower limit-40%,Output voltage was single phase:220/230/240VAC,Defult 220VAC,Output accuracy was ±1%,Output frequency was Defult 50Hz±0.05%. 60Hz optional,Peak output current ratio was 3:1,Output waveform distortion was <1%(linear load;<3%(Nonlinear load),Output power factor was PF = 0.9,Overload capacity:<110%Rated load, sustainable operation;110%-125%,Rated load 10 min;125%-150%,Rated load 60S;,Efficiency was 0.92,Battery topology was Battery direct hanging DC bus,Battery DC voltage was DC384V 3/1(360V,372V,384V,396V,408V),Voltage range of inverter operation was 300~460VDC,Built in switch configuration include:Main circuit breaker, bypass switch, maintenance switch, output switch, battery switch (some models),Transformer:DC384V:Built in output isolation transformer,Entry method was Offline entry line,Battery backup time (25 ℃):Depends on user needs and configuration,Battery charging time:8-30H,Display:7-inch color touch screen with 3 LED status indicators,Protection level:The internal PCBA has three proof paint, up to IP42 (optional),Conversion time was 0ms(online mode to battery mode);<0ms(battery mode to bypass mode).Operating temperature was 0~40℃ (40 ~ 50℃ Need to reduce the amount),Relative humidity was 0-95% No condensation,UPS Dimensions was 1100*800*1800mm (W*D*H),UPS Net weight:935KG,Audio noise:<50dB @ at a distance of 1 meter,Operating altitude:0~3000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output.,Execution standards:Compliant with standards:IEC62040-2, IEC62040-3.Communication and monitoring:Supports RS485; EPO button; Standard configuration includes 1 input dry contact and 2 output dry contact signals; Mini Plot communication card,Optional Accessories:Parallel components; Industrial network checkpoint, second-generation environmental probe; Battery cold start components; Load bus synchronization group (LBS); Insulation tester,Parallel redundancy(optional):Max can install 8 UPS units; Shared battery pack,Warranty:3 year.Application scenarios:Electric power industry, DCS discrete control system, generator transformer protection system, desulfurization control system; Petroleum and petrochemicals, oil and gas collection systems, pipeline transmission systems, oil and gas storage and transportation systems, refining systems; Steel and coal manufacturing industry, DCS distributed control system, industrial computer and display screen, PLC control system; Rail transportation industry, vehicle/airport ground power system, integrated security system, communication signal system, integrated monitoring system; Light/Heavy Industry
Product Features
- Industrial grade protection design: Three proof coating on circuit board+independent heat dissipation duct, suitable for wide temperature range of -25℃~55℃and high dust environment.
- High reliability architecture: Output transformer vacuum impregnation treatment, redundant power supply and fan, passed 100% factory aging test.
- Isolation transformer standard configuration: Block DC components and common mode interference to ensure the safety of sensitive loads such as PLC and DCS.
- Intelligent communication integration: Supports MODBUS TCP/RTU protocol, seamlessly integrates with BMS system, and executes remote commands accurately.
- Wide input adaptability: wide voltage/frequency range+soft start design, compatible with generators and fluctuating power grids.
- Anti impact load capacity: specially optimized for industrial impact loads such as motors and pumps, with output stability increased by 40%.
- Full scenario power purification: solves 11 types of power problems such as harmonics and voltage drops, and outputs pure sine waves.
- Strict environmental certification: Passed seismic and corrosion resistance tests, suitable for heavy industrial scenarios such as petrochemicals, manufacturing, and rail transit.
Application Scenarios
- Electric power industry, DCS discrete control system, generator transformer protection system, desulfurization control system; Petroleum and petrochemicals, oil and gas collection systems, pipeline transmission systems, oil and gas storage and transportation systems, refining systems; Steel and coal manufacturing industry, DCS distributed control system, industrial computer and display screen, PLC control system; Rail transportation industry, vehicle/airport ground power system, integrated security system, communication signal system, integrated monitoring system; Light/Heavy Industry
Product Parameters
- Brand:SANTAK
- Product-type:Uninterruptible power system
- Series:SANTAK Industrial UPS SIU series (10-200KVA)
- Topology:Online (dual conversion)
- Backup type:Long lasting model (external battery)
- System:Three phase input/single-phase output
- Product Category:Industrial UPS
- Model:SIU100K-316PFXC
- Load power(max):100kVA/90kW
- Type of power system:TN-S, TN-C, TN-C-S, TT, IT
- Input/output voltage phase:Three phase input/single-phase output
- Input method:Three phase without N line(L1/L2/L3/G)
- Rated voltage:three phase:380/400/415VAC
- Input Voltage:285VAC-498VAC
- Input frequency:Rated 50/60Hz;Frequency range:45-66Hz
- THDI:6 pulse add 5th filter:≤10%
- Input power factor:6 pulse add 5th filter:≥0.92
- Bypass voltage:single phase:220/230/240VAC,Default 220VAC
- Bypass input voltage range:Default upper limit+20%,Default lower limit-40%
- Bypass input frequency range:50/60Hz ±10%
- Output voltage:single phase:220/230/240VAC,Defult 220VAC
- Output accuracy:±1%
- Output frequency:Defult 50Hz±0.05%. 60Hz optional
- Peak output current ratio:3:1
- Output waveform distortion:<1%(linear load;<3%(Nonlinear load)
- Output power factor:PF = 0.9
- Overload capacity:<110%Rated load, sustainable operation;110%-125%,Rated load 10 min;125%-150%,Rated load 60S;
- Efficiency:0.92
- Battery topology:Battery direct hanging DC bus
- Battery DC voltage:DC384V 3/1(360V,372V,384V,396V,408V)
- Conversion time:0ms(online mode to battery mode);<0ms(battery mode to bypass mode)
- Voltage range of inverter operation:300~460VDC
- Battery backup time (25 ℃):Depends on user needs and configuration
- Battery charging time:8-30H
- Built in switch configuration:Main circuit breaker, bypass switch, maintenance switch, output switch, battery switch (some models)
- Transformer:DC384V:Built in output isolation transformer
- Entry method:Offline entry line
- Display:7-inch color touch screen with 3 LED status indicators
- UPS Dimensions(W×D×H)(mm):1100*800*1800
- UPS Net weight(kg):935
- Operating temperature:0~40℃ (40 ~ 50℃ Need to reduce the amount)
- Storage temperature:-15 ~ 70℃
- Relative humidity:0-95% No condensation
- Audio noise (at a distance of 1 meter):<50dB @ at a distance of 1 meter
- Protection level:The internal PCBA has three proof paint, up to IP42 (optional)
- Operating altitude:0~3000m;If UPS is used at an altitude of over 1000m, it must use a decreasing rated output.
- Execution standards:Compliant with standards:IEC62040-2, IEC62040-3
- Communication and monitoring:Supports RS485; EPO button; Standard configuration includes 1 input dry contact and 2 output dry contact signals; Mini Plot communication card
- Optional Accessories:Parallel components; Industrial network checkpoint, second-generation environmental probe; Battery cold start components; Load bus synchronization group (LBS); Insulation tester
- Parallel redundancy(optional):Max can install 8 UPS units; Shared battery pack
- Warranty:3 year
- Note-1:Industrial grade UPS (industrial machine): capable of continuously and stably ensuring load power supply in harsh environments; Applied in industrial production fields, such as manufacturing workshops, factory production lines, and other high dust, high humidity, and corrosive gas containing scenarios; The load types include impact loads such as water pumps and motors, as well as capacitive loads.
- Note-2:This product is used in Class C2 environments and requires additional measures to suppress electromagnetic interference. This product is suitable for C3 class environments, including all commercial and industrial environments.